BMCVM - POLAR PATCH - LOW TEMP PART A F-141-LT

  • MSDS: BMCVM
  • Manufacturer: PIONEER RANDUSTRIAL
  • Product Name: POLAR PATCH - LOW TEMP PART A F-141-LT
  • National Stock Number: 8030-00N026142
Product Identification

Product ID:POLAR PATCH - LOW TEMP PART A F-141-LT
MSDS Date:02/01/1989
FSC:8030
NIIN:00N026142
Kit Part:Y
MSDS Number: BMCVM

Responsible Party
PIONEER/RANDUSTRIAL
CLEVELAND, OH 44134
US

Emergency Phone: 216-749-3100

Info Phone: 216-749-3100

Preparer: ASHOK A. GANAPATHY

Cage: 47372

Contractor
PIONEER
34085 CLEVELAND, OH 44135 US

Telephone: 216-749-3100, 800-877-1500

Cage: 47372

Ingredients

UNSATURATED POLYESTER

Fraction By Weight: 52%


STYRENE; (STYRENE MONOMER)

CAS: 100-42-5

RTECS: WL3675000

Fraction By Weight: 47.9%

OSHA PEL 100 PPM

ACGIH TLV: S,50PPM/100STEL;9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ANILINE, N,N-DIETHYL; (DIETHYL ANILINE)

CAS: 91-66-7

RTECS: BX3400000

Fraction By Weight: 0.1%

ACGIH TLV: 5 PPM, S (MFR)

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:STYRENE AT 100 PPM OR IN STRONG
CONCENTRATION IS IRRITATING TO ALL PARTS OF THE RESPIRATORY TRACT
AND EYES. MAY BE FATAL AT 10,000 PPM. SOMEWHAT ANESTHETIC.
Explanation of Carcinogenicity:STYRENE: GROUP 2B (IARC).
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE FROM EXPOSURE TO WELL VENTILATED AREA. MAKE
COMFORTABLY WARM BUT NOT TOO HOT. USE O2 OR ARTF RESP AS REQUIRED.
EYES: FLUSH PROMPTLY W/COPIOUS AMOUNTS OF WATER FOR A MINIMUM OF 15
MIN & S EEK MEDICAL ATTN. SKIN: REMOVE SATURATED CLOTHING PROMPTLY
AND WASH AFFECTED AREAS WITH SOAP & WATER. INGEST: CALL MD
IMMEDIATELY .

Fire Fighting

Flash Point Method:SCC
Flash Point:89.0F,31.7C
Extinguishing Media:CARBON DIOXIDE, FOAM OR DRY CHEMICAL.
Fire Fighting Procedures:FIGHT LIKE A FUEL OIL FIRE. WEAR NIOSH/MSHA
APPROVED SCBA & FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:STYRENE WILL POLYMERIZE READILY AT
ELEVATED TEMP SUCH AS FIRE CNDTNS. IF THIS OCCURS IN A CLOSED
CONTR, THERE IS POSSIBILITY OF VIOLENT RUPTURE.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAME, HEAT &
SPARKS). VENTILATE AREA. ABSORB W/INERT MATLS SUCH AS VERMICULITE
OR SAND & PLACE IN CLOSED CONTRS FOR DISPOSAL AS SOLID WASTE. WASH
AREA WELL W/ TRISODIU M PHOSPHATE & WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID IMPROPER ADDITION OF PROMOTER
&/OR CATALYST. CONSULT PROD BULLETIN. A PROMOTER (METAL ORGANIC
SUCH AS COBALT OR ANILINE TYPE) AND (SUPP DATA)
Other Precautions:THIS PROD CONTAINS TOXIC CHEM (STYRENE -
CAS#100-42-5) SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313
OF THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW ACT OF 1986
AND OF 40 CFR 372.

Exposure Controls

Respiratory Protection:UP TO 100 PPM, NONE. IF EXCEEDED, USE NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:NEOPRENE OR NON-SOLUBLE PLASTIC.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SAFETY SHOWERS & EYE WASH STATIONS SHOULD BE
AVAILABLE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
KEY1:F4. HNDLG/STOR PREC: CATALYST (ORGANIC PEROXIDE TYPE) USED WITH
THIS PROD SHOULD ALWAYS BE MIXED SEPARATELY W/THE PROD & SHOULD
NEVER BE MIXED DIRECTLY TOGETHER.

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:145F,63C
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, PEROXIDES AND OTHER OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Conditions to Avoid Polymerization:SUNLIGHT, OPEN FLAMES, CONTAMINATION
& PROLONGED STORAGE ABOVE 100F.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH LOCAL,
STATE, AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.